Holding the supplied RESET card in front of the RFID reader of the charging station resets the go-e Charger PRO to factory settings (confirmation: the LED ring briefly lights up red). This makes sense, for example, if the Wi-Fi/device password has been forgotten or there is a misconfiguration. Afterwards, all settings made via the app must be set up again during commissioning.
What is kept according to the manufacturer
- Saved RFID chips
- Assigned consumption data
All other configurations made via the go-e app are reset to factory state!
Checklist: what to set again afterwards:
1. Reconnect to the charging station
After the reset, the charging station is back in hotspot mode. Reconnect with the go-e app. The credentials (hotspot SSID, hotspot password/"hotspot key", QR code) are printed on the RESET card.
2. Set up the network/Wi-Fi again
If no network cable is connected: select the Wi-Fi network again and enter the password (or check the LAN/Ethernet connection if the station is wired).
3. Set the charging current/power setting again
By default, the charging station is limited to 16 A / 11 kW again after the reset. If 22 kW (32 A, three-phase) is required, this must be set again. A technician password has to be assigned again for this. (22 kW variant expected to be available from Q1 2027)
4. Assign the device password again (if it was changed before)
After the reset, the default password (hotspot key from the RESET card) applies again. If an individual password was used for security reasons, it must be set again.
5. neoom-specific: Reactivate Modbus TCP / API access
To integrate with neoom CONNECT, the following must be activated again under "Advanced settings":
- "Allow local Modbus TCP API" → ON
- "Swap registers" → ON
- "Swap bytes" → ON
Without these three settings, the charging station is no longer reachable for neoom Ai, even if it was already integrated before.
6. neoom Ai: Check the connection
- The IP address of the charging station usually remains unchanged if it is assigned via a fixed/reserved assignment in the customer's router (a router-side setting, not affected by the reset of the charging station). To be verified.
- As long as IP, port (502) and unit ID (1) are unchanged, no new device needs to be created in the neoom CONNECT site. The existing device tile will show offline/error until item 5 (Modbus TCP) is active again.
- After restoring the Modbus TCP settings, it is recommended to click "Konfiguration übernehmen" once in the site configuration to refresh the connection.
7. Check other comfort/operating settings used previously
Depending on what was configured at the site beforehand, also set or check the following:
- Charging mode (Eco / Basic / Daily Trip)
- Access control / authentication required (open vs. RFID required, local or cloud). To be verified whether this mode survives the reset
- Load management (static/dynamic) and fallback limit
- OCPP configuration (server address, activation)
- If applicable, ripple control receiver/grid operator control (digital input), if configured via the app
Sources
- go-e Charger PRO CABLE / CABLE ME, installation and operating manual, V1.0 (go-e GmbH), section "Reset to factory settings": <https://go-e.com/fileadmin/Support/Anleitungen/Deutsch/go-e-charger-pro-installations-und-bedienungsanleitung.pdf>
- go-e support FAQs: <https://go-e.com/en/support/faqs>