Charging stations in a Main / Support group:

Charging stations such as the KEBA KeContact P30 can be configured in a master-slave group.

Charging station Main Support configuration overview in neoom CONNECT

However, this is only possible if the charging station supports it and is integrated via OCPP.

Setting up the Main charging station:

Charging station Main Support configuration Main

Setting up the Support charging stations:

Charging station Main Support configuration Support

When the charging station is integrated via OCPP, RFID cards for access authorization can be configured in neoom Ai. This is only possible on the Main charging station. The entered RFID card numbers are also applied to the Support charging stations.

With an OCPP connection, CONNECTOR ID 1 must be entered for the Main charging station. The Support charging stations should each be given a unique Connector ID other than 1. A Connector ID only has to be unique per charging station; within a group, it depends on the connection to the backend.

The Charger ID is a pre-filled, automatically generated number, which can be changed if needed.

Charging stations with multiple charging points:

In earlier neoom Ai versions, charging stations integrated via OCPP with multiple charging points had to be created as separate devices. This has now been changed, so it is possible to set up several so-called device components (charging points) for one device (charging station):

Configuring charging stations with multiple charging points in CONNECT