C-rate

Charge or discharge rate

Ratio of charge or discharge current to battery capacity. Example: C 1 = 1 h until full, C 0.5 = 2 h, C 2 = 0.5 h

CCS

Combined Charging System

Charging standard for electric vehicles with the variants CCS1 and CCS2

CCS1

Variant of CCS

mainly in North America, based on the Type 1 plug (SAE J1772)

CCS2

Variant of CCS

in Europe and many other countries, based on the Type 2 plug (IEC 62196)

DoD

Depth of Discharge

Discharge depth of a battery

EPS

Emergency Power Supply

Backup power: during a power outage the storage system or the PV system keeps the power supply running

FRT

Fault Ride Through

Ability of a PV system to stay in operation during short voltage dips in the grid

MPP tracker

Maximum Power Point Tracker

continuously adjusts voltage and current of the solar modules so that they deliver maximum power (Maximum Power Point, MPP)

OCPP

Open Charge Point Protocol

open communication standard between charging stations and central management systems

RCMU

Residual Current Monitoring Unit

monitors the residual current in PV systems and safely shuts the system down in case of a fault, e.g. an earth fault

SoC

State of Charge

current charge level of a battery (SoC calculation, in German)

SoH

State of Health

health of a battery in %